Heathkit Zenith SP-2717A Power Supply Restore

This is one of the gear I acquired long ago. This is not much fun or expertise needed to restore this, as it simple regulated power supply with Tubes. Thought will share the procedure just in case someone is looking for some guidelines.

CAUTION:

Read this  CAREFULLY  before you proceed.

This is a very dangerous instrument in terms of the voltage levels. It can deliver lethal DC and AC Voltages at substantial current levels to RIP you in one shot. AC voltage at “Secondary” is as high as 300V. DC levels can reach over 450V. There are better ways to die if you are up to that.

DO NOT ATTEMPT TO REPAIR/RESTORE ONE OF THESE UNLESS YOU ARE QUALIFIED AND KNOWS WHAT YOU ARE DOING AND HAVE THE RIGHT TOOLS, PROBES AND FOLLOWS ALL SAFETY PRECAUTIONS.

EVEN IF YOU ARE QUALIFIED, PLEASE DO TAKE GOOD CARE AND ATTENTION WHILE WORKING ON THIS.

This was the condition when I picked it up,

Any vintage instrument like this, first rule is to do a detailed inspection. Never even think of powering it up. Not that it  damages  itself, which will be irrecoverable, as parts may not be available in some cases.

First Glance at Panel. I notice rust on the screws, output sockets have oxidation.

4

Lets look at inside, like I mentioned before, there is nothing exciting here to troubleshoot.

Typical vintage gear with leaky/Bulged caps, rusted screws. Notice the PCB is kinda burned because the person who assembled this put the zener way too close to be board. They do get hot and was burning the board. Dust all over inside as expected.

62

Now, first step is to remove the caps and inspect in detail. Also if you observe there are not protection around terminals. I like to heat-shrink those terminals when I restore things.

Time to clean the chassis, connectors, check for cracked wiring, rust, and I did re-solder few points.

These are not factory made products. Its assembled by someone. Highly advised to check the wiring, with schematic, as there could be mistakes in the whole assembly/wiring.

Time to check the tubes out. There are only three, 6AU6 Pentode and 6L6GC beam Pentode as the main series regulator. For me the 6AU6 was bad, shorted. Decided to change as I had it in stock. Luckily main Pentodes were testing good in the Tube tester.

 

I didn’t have the caps in stock, so ordered caps. Decided to order the best in the class as I can not take risk at 450V or wanna risk my regulator tubes being burned.

While waiting for caps to arrive, decided to fix rest of the issues. I personally don’t like rusted screws, one POT was rusted too. I cant replace the POT so repainted it, but replaced all screws. Removed the Volt meter selector switch and cleaned it too.

Time for Electrical troubleshooting.  As expected, many of the zener diodes were shorted.  I assume this be due to overheating.This is a 27V Zener. The design use them in series to get the high voltage reference they need.

Trip to HSC (Halted Supplies ) or Excess solutions  got me those diodes ( I am in no way affiliated with neither of these).

Caps arrived too, and time to put things together.

24

[ You will see some box caps, they are the precision 1% tolerance ones ordered for EICO 950B, check the post on that in case you wonder what that is]

WARNING

CLEAN THE FLUX AFTER SOLDERING WITH ALCOHOL. VOLTAGE LEVELS ARE SO HIGH THEY CAN ARC THROUGH FLUX AND CATCH FIRE.

Here is the rest of the process in pictures. I replaced the front panel indicator 6.3v Lamps with LEDs. Remember Raise the Zener off the board, as much as you can to provide cooling. They do get hot.

Now, time to power up. Disconnected the HV Transformer and keep only the Filament transformer in circuit and use variac to power up and ensure tubes are glowin.

29

 

And the Filament voltage on the front panel is delivering 6.3 and 12.6 (output will be slightly over this as there is no load). The VTVM in the rear is reading the 12.6V output from front panel.

34

 

Now time to connect main transformer and monitor main output. Do ramp power slowly via Variac, check regulation, output levels.

If you checked all components and fixed the faulty ones, it should be working like above. You can see the -output and +ve output. The Fluke output shows the +400V output.

The last picture is with a load on the +Ve rail to show the ammeter in action.

CAUTION : -ve rail is for Grid. Its regulated by the resistance of  -ve voltage control Potentiometer in front panel. There is no active component involved to deliver high current.  Do not connect anything heavy to it. It will burn the Potentiometer.

And here is the left over from the whole restore project.

Back to Home Page for More Crazy Stuff

 

 

 

 

Advertisements

4 thoughts on “Heathkit Zenith SP-2717A Power Supply Restore

  1. This was a great read and you seem to know your stuff (I do not). I found this because I just came across one of these exact units at work (it JUST failed after 37 years in service), and the lab is getting rid of it. I wondered if you want it? it is in MUCH better shape then the one you describe here (not corrosion, caps all look to be in good shape). It has two extra smaller tubes then the one you show us, and they do not seem to work, but I do not know. You can contact me at xxxxxx@gmail.com if you are interested in it and some other items that you may like.

    Like

  2. @LazyElectrons I’m also looking to get one of these. Is there any particular difference between the IP-17 and IP-2717? These units seem to be becoming pricier over time.

    There are a bunch of the SP Schlumberger series of the same online for sales but they seem to go for $200+.

    Like

  3. I dont have IP-17, but I checked the schematics online and looks like mainly its on the rectifier and VR side. IP-17 uses 0A2 VR Tubes instead of Zener in the 2717 , and also for one stage of rectification, IP-17 use 6X4, whereas on the 2717 its diodes.

    Like

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google+ photo

You are commenting using your Google+ account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s